Honeycomb Paper Board FAQ: Compression, Cell Size and Humidity

Published: 2026-10-24

Honeycomb board is sold as a strong, light panel, and the strength claim is where most of the confusion starts. These questions cover what carries the load, why a dry test misleads, and how a buyer can write a specification that a supplier cannot satisfy with a favourable sample.

What carries the load in a honeycomb panel?

The cell walls, along the axis of the cells. A panel is a set of paper walls standing on edge between two faces, so compression is carried by the total wall area rather than by the thickness. That is why a taller cell adds bending stiffness and almost nothing to edge crush. When a crate fails by crushing at the frame, the fix is a smaller cell, a heavier paper or a solid insert at the load point, not a thicker panel. When a large unsupported panel bows, thickness helps. Identify the failure mode from the damaged panel before buying anything, because the two failures are solved by opposite changes and a supplier will happily sell the one that is easier to make.

Why does the panel lose strength in a container?

Because paper is hygroscopic. At high relative humidity the fiber softens, and a cell wall that is stiff at moderate humidity becomes flexible at high humidity. A container on a deck route cycles in temperature every day, and moisture migrates toward the colder surface, which is often the panel nearest the steel shell. Six weeks of that changes the failure mode from crushing to buckling. The specification should therefore carry a compression figure at a stated humidity, not a single dry number, and the pack should include moisture control for a humid route: a coated face, a barrier liner around the crate and a desiccant inside the wrap.

ASTM International publishes test methods for paperboard and shipping containers, including compression and conditioning procedures, giving a basis for comparing structural panels under the same conditions.
ASTM International, https://www.astm.org

Why does the same panel test differently in two labs?

Because the test conditions differ: the cell axis orientation, the sample size, the loading rate, the conditioning time and the way the load is applied. A small sample tested between flat platens gives a higher figure than a full panel loaded through a frame, because the platen restrains the edges. A short conditioning time gives a drier sample and a higher number. Ask for the conditioning time, temperature and humidity, the sample size, the loading rate and the jig. If a supplier cannot supply those five details, the number is not comparable with anything, including the supplier's own previous number. When two labs disagree, test the same conditioned samples in both and compare the method before comparing the board.

How should the specification be written?

Six lines: cell size and cell height, paper grade with basis weight, load direction relative to the cell axis, compression strength at a stated humidity, edge treatment and the frame contact detail, plus the load case with stack height and storage duration. Add the moisture control for the route and the inspection method per lot. The load case is the line that prevents most failures, because a panel approved for a three-high stack can be crushed by a four-high one and the panel will be blamed. Review the specification when the product, the pallet pattern or the route changes, and keep the revision record so a complaint can be judged against the drawing that was in force.

The International Safe Transit Association publishes distribution test procedures that can be applied to a packed crate so that the panel is validated against the route rather than against the plant floor.
International Safe Transit Association, https://www.ista.org

What should be inspected per lot?

Thickness at five points, a sample weight to check the basis weight, the cell count over a measured length from a cut section, and a compression test on a conditioned sample with the frame jig. Record values rather than pass marks so a drift is visible. Keep a photograph of the section, because the cell shape shows whether the material is what was ordered. A supplier who resists a conditioned test is telling you that the dry number is the only one that flatters the product, and that is the single most useful piece of information a buyer can get from a first meeting.

When is honeycomb the wrong choice?

When the load is concentrated on a small area, when the pack will be wet for long periods, or when the crate needs to be reused many times. A solid wood or plywood member at a concentrated load point is often cheaper than a heavier panel, and a coated panel is not a substitute for a dry pack. Honeycomb is at its best as a shear web in a framed crate with a dry route and a defined stack. Asking a supplier to solve a wet, concentrated, repeated-use case with a paper panel is the fastest way to a claim that both sides will lose.

How should the crate frame be detailed?

The frame should collect the load and hand it to the panel along a line, not at a point. That means a continuous member at the top and bottom of each panel, corner blocks that are glued and stapled rather than stapled alone, and a joint that does not rely on the panel face to hold a fastener in tension. Where a panel meets a concentrated load, insert a solid block or a denser strip rather than thickening the whole panel, because the load is local and the cost should be local too. Draw the joint at scale and check it in a stack test, since a detail that looks adequate in a section can crush the open cells at the panel edge. Fasteners should sit at least a cell width away from the cut edge, or the cell wall will split and the joint will loosen under vibration.

How is a stack test run?

Build the real crate, load it with the real product, and stack it to the height the customer will use, then hold it for the storage duration at the storage humidity. Measure the deflection of the bottom crate at the start, the middle and the end, and inspect the panels for buckling, crushing at the frame and separation at the joints. A short test at room humidity will pass almost any panel; the value comes from the duration and the humidity, because paper creeps and softens with time. Photograph the failure if there is one and label it by mode, so the next design change is aimed at the right property. Repeat the test after a design change rather than assuming that a heavier paper solved a geometry problem.

One closing note on cost: price the panel by the square metre at the specified grade, and compare quotes only when the cell size and the paper weight match. A quote that is cheaper because the cell is larger is a different product, and the crate will find out on the first shipment. Ask for the cell count and the basis weight on the quotation itself, so that two offers can be compared line by line without a meeting.